Model No.: HLG-185H-24
Brand: Meanwell
Usage: Vehicle
Output Type: Single
Driving Method: LED Regulator Voltage
Circuit Structure: Electronic Step-down Transformer
Certification: ROSH
Power Supply Mode: Constant Voltage Source
In-Out: Step-down Type
Power Supply Voltage: AC85-265
Warranty: 5 Years
SAFETY STANDARDS: UL60950-1 Approved
Packaging: Box
Productivity: 20000pcs per month
Transportation: Ocean,Land,Air
Place of Origin: Guangdong, China
Supply Ability: 5000pcs per month
Port: Shenzhen,Guangzhou,Hongkong
Payment Type: T/T,Paypal,Money Gram,Western Union
Incoterm: FOB,CIF
Meanwell 185W Waterproof IP65 Power Supply
Products Description
Waterproof 185W Single Output Switching Power Supply, the following model widely used with Iseeled`s led lamps, HLG-185H-12, HLG-185H-15, HLG-185H-24,etc some other model for special lamps with different input voltage.
HLG-185H-12 Blank : IP67 rated. Cable for I/O connection.
HLG-185H-12A : IP65 rated. Output voltage and constant current level can be adjusted through internal potentiometer.
HLG-185H-12B : IP67 rated. Constant current level adjustable through output cable with 1~10Vdc or PWM signal or resistance.
HLG-185H-12D (option) : IP67 rated. Timer dimming function, contact MEAN WELL for details.
Model | HLG-185H-12 | HLG-185H-15 | HLG-185H-24 | ||
Output | DC VOLTAGE | 12V | 15V | 24V | |
CURRENT ADJ. RANGE | Can be adjusted by internal potentiometer A type only | ||||
6.5-13A | 5.75-11.5A | 3.9-7.8A | |||
RATED POWER | 156W | 172.5W | 187.5W | ||
VOLTAGE ADJ. RANGE | 10.8-13.5V | 13.5-17V | 22-27V | ||
Input | Voltage Range | 90-264VAC 127-370V DC | |||
Frequency Range | 47-63Hz | ||||
POWER FACTOR | PF>0.98/115VAC, PF>0.95/230VAC, at full load (Please refer to "Power Factor Characteristic" curve) | ||||
Efficiency(Typ.)(230Vac) | 92% | 93% | 94% | ||
AC CURRENT (Typ.) | 12V | 1.8A / 115VAC 0.8A / 230VAC | |||
15V ~ 54V | 2.1A / 115VAC 0.9A / 230VAC | ||||
INRUSH CURRENT(Typ.) | COLD START 75A/230VAC | ||||
LEAKAGE CURRENT | <0.75mA / 240VAC | ||||
PROTECTION | OVER LOAD | 95~ 108% | |||
Protection type : Constant current limiting, recovers automatically after fault condition is removed | |||||
SHORT CIRCUIT | Constant current limiting, recovers automatically after fault condition is removed | ||||
OVER VOLTAGE | 14-17V | 18-21V | 28-34V | ||
Protection type :Shut down O/P voltage, re-power on to recover | |||||
OVER TEMPERATURE | 100 ℃ up or less10 ℃ (RTH2) | ||||
Protection type : Shut down and latch off o/p voltage, recovers automatically after temperature goes down | |||||
Environment | WORKING TEMP. | -40 ~ +70 ℃(Refer to output load derating curve) | |||
WORKING HUMIDITY | 20 ~ 95% RH non-condensing | ||||
SAFETY | SAFETY STANDARDS | UL8750, CSA C22.2 No. 250.0-08, EN61347-1, EN61347-2-13 independent IP65 or IP67, J61347-1, J61347-2-13 approved ; design refer to UL60950-1, TUV EN60950-1 | |||
WITHSTAND VOLTAGE | I/P-O/P:3.75KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC | ||||
ISOLATION RESISTANCE | I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC / 25 / 70% RH | ||||
EMC EMISSION | Compliance to EN55015, EN55022 (CISPR22) Class B, EN61000-3-2 Class C ( 50% load) ; EN61000-3-3 | ||||
EMC IMMUNITY | Compliance to EN61000-4-2,3,4,5,6,8,11, EN61547, EN55024, light industry level (surge 4KV), criteria A | ||||
Others | MTBF | 192.2K hrs min. MIL-HDBK-217F (25℃ ) | |||
DIMENSION | 228*68*38.8mm (L*W*H) | ||||
PACKING | 1.15Kg; 12pcs/14.8Kg/0.8CUFT |
Note
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Derating may be needed under low input voltages. Please check the static characteristics for more details.
5. Type A only.
6. Safety and EMC design refer to EN60598-1, CNS15233, GB7000.1, FCC part18.
7. Length of set up time is measured at cold first start. Turning ON/OFF the power supply may lead to increase of the set up time.
8. The power supply is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.
9. Refer to warranty statement.
Product Categories : LED Accessories > Meanwell Waterproof Power Supply
Privacy statement: Your privacy is very important to Us. Our company promises not to disclose your personal information to any external company with out your explicit permission.
Fill in more information so that we can get in touch with you faster
Privacy statement: Your privacy is very important to Us. Our company promises not to disclose your personal information to any external company with out your explicit permission.